1,     For high-power pumps, the pump - motor assembly should not be mounted on the tank, and the mounting table should be made of rigid materials. The pump and motor should be supported on a common basis and supported on a common basis, and the lower feet should be fixed securely.

2,     Install the hydraulic pump bracket to be firm, rigid, and fully absorb vibration.

3,     The drain tube of each pump should be connected back to the tank separately. Do not share a return line with the system return line. Because the back pressure of the system often occurs with high back pressure, if the two pipes are combined, the pressure inside the pump will increase due to the increase of the back pressure of the total return pipe. The oil leakage at the oil seal of the pump shaft and the oil seal are repeatedly broken. The phenomenon of general pump drain pipe back pressure should not exceed 0.3MPa .

4,     The inlet pipe of the pump cannot be connected to the return pipe of the overflow valve, because the return pipe of the overflow valve discharges hot oil. If the hot oil is sucked into the pump without cooling the tank, it will cause a vicious circle of temperature rise of the hydraulic system. The higher the higher, leading to many failures.

5,     A layer of anti-vibration hard rubber should be installed between the motor base and the motor ; the coupling between the pump and the motor should use a flexible coupling, and the length of the connection between the shaft and the coupling should be less than 2/3 . , And with a good fit, remove the coupling to use special tools such as puller, be sure to install the coupling to avoid hitting the pump shaft.

6,     Regardless of whether the pump is installed with a flanged round bearing or a right-angled bearing, the different axes of the two axes shall not be greater than 0. 05mm . If an elastic or flexible coupling is used, the different axes of the two axes shall not be greater than 0.1mm . The two-axis angular error should be controlled within 0.5 degrees.
The end of the drive shaft and the end of the pump should be kept at a distance of 2-3 mm . The elastic coupling should be used. There should be 3 mm gap between the two end surfaces of the pump to prevent the pump shaft and motor shaft from dying.

7,     Pump suction height must not be greater than the low oil level 500mm.

8,     Try not to use the drive belt, chain and gear to drive the pump, because it will make the pump to withstand a large radial load, causing partial wear of the pump components, shorten the pump's life. When it is imperative to do so, take measures to reduce radial forces on the shaft.

9,     The suction pipe diameter of the hydraulic pump shall not be less than the pump inlet diameter, and the suction flow rate of the suction oil filter shall not be less than twice the flow rate of the hydraulic pump.

The above information is provided by Weiwang Machinery - liquid oil pump manufacturer! For updated information see:

문의하기

Author:

Ms. Alice

이메일:

info@dyhydr.com

Phone/WhatsApp:

+8617616058688

인기 상품
You may also like
Related Categories

이 업체에게 이메일로 보내기

제목:
이메일:
메시지:

Your message must be betwwen 20-8000 characters

We will contact you immediately

Fill in more information so that we can get in touch with you faster

Privacy statement: Your privacy is very important to Us. Our company promises not to disclose your personal information to any external company with out your explicit permission.

송신